Wednesday, March 26, 2008

Basics Hardware components for Fibre Channel SAN

Basics Hardware components for Fibre Channel SAN

Within the scope of this book we can only introduce the most important product groups. It is not worth trying to give an overview of specific products or a detailed description of individual products due to the short product cycles. This section mentions once again some product groups that have been discussed previously and introduces some product groups that have not yet been discussed. It is self-evident that servers and storage devices are connected to a Fibre Channel network. In the server this can be achieved by fiting the host bus adapter cards (HBAs) of different manufacturers, with each manufacturer offering different HBAs with differing performance features. In storage devices the same HBAs are normally used. However, the manufacturers of storage devices restrict the selection of HBAs. Of course, cables and connectors are required for cabling. In Section 3.3.2 we discussed different copper and fiber-optic cables and their properties. Various connector types are currently on offer for all cable types. It may sound banal, but in practice the installation of a Fibre Channel SAN is sometimes delayed because the connectors on the cable do not fit the connectors on the end devices, hubs and switches and a suitable adapter is not

to hand. A further, initially improbably, but important device is the so-called Fibre Channel-to- SCSI bridge. As the name suggests, a Fibre Channel-to-SCSI bridge creates a connection between Fibre Channel and SCSI (Figure 3.30). These bridges have two important fields of application. First, old storage devices often cannot be converted from SCSI to Fibre Channel. If the old devices are still functional they can continue to be used in the Fibre Channel SAN by the deployment of a Fibre Channel-to-SCSI bridge. Second, new tape libraries in particular often initially only support SCSI; the conversion to Fibre Channel is often not planned until later.With a Fibre Channel-to-SCSI bridge the newest tape libraries can be operated directly in a Fibre Channel SAN and Fibre Channel connections retrofitted as soon as they become available. Unfortunately, the manufacturers have not agreed upon consistent name for this type of device. In addition to Fibre Channel-to-SCSI bridge, terms such as SAN router or storage gateway are also common. The switch is the control centre of the fabric topology. It provides routing and aliasing, name server and zoning functions. Fibre Channel switches support both cut-through routing and the buffering of frames. In new switches a number of ports between eight and about 250 and a data transfer rate of 200 MByte/s should currently (2003) be viewed as standard. In Fibre Channel SANs that have already been installed, however, a large base of switches exists that still work at 100 MByte/s.

 

 

Resilient, enterprise-class switches are commonly referred to as 'directors', named after the switching technology used in mainframe ESCON cabling. Like Fibre Channel switches they provide routing, alias names, name server and zoning functions. Fibre Channel direc- tors are designed to avoid any single point of failure, having for instance two backplanes and two controllers. Current directors (2003) have between 64 and 256 ports. Designing a SAN often raises the question whether several complementary switches or a single director should be preferred. As described, directors are more fault-tolerant than switches, but they are more expensive per port. Therefore, designers of small entry-level SANs commonly choose two complementary Fibre Channel switches, with mutual traffic fail-over in case of a switch or a I/O path failure (Figure 3.31). Designers of larger Fibre Channel SANs often favour directors due to the number of ports currently available per device and the resulting layout simplicity. However, this argument in favour of directors becomes more and more obsolete since today switches with a greater number of ports are available as well. SANs running especially critical applications, e.g. stock market banking or flight control,

would use complementary directors with mutual traffic failover, even though these directors already avoid internal single points of failure. This is similar to wearing trousers with a belt and braces in addition: protecting against double or triple failures. In less critical cases, a single director or a dual complementary switch solution will be considered sufficient. If we disregard the number of ports and the cost, the decision for a switch or a director in an Open Systems Fibre Channel network primarily comes down to fault-tolerance of

 

an individual component. For the sake of simplicity we will use the term 'Fibre Channel switch' throughout this book in place of 'Fibre Channel switch or Fibre Channel director'. A hub simplifies the cabling of an arbitrated loop. Hubs are transparent from the point of view of the connected devices. This means that hubs send on the signals of the connected devices; in contrast to a Fibre Channel switch, however, the connected devices do not communicate with the hub. Hubs change the physical cabling from a ring to a star-shape. Hubs bridge across defective and switched-off devices, so that the physical

ring is maintained for the other devices. The arbitrated loop protocol is located above this cabling. Hubs are divided into unmanaged hubs, managed hubs and switched hubs. Unman- aged hubs are the cheap version of hubs: they can only bridge across switched-off devices. However, they can neither intervene in the event of protocol infringements by an end device nor indicate the state of the hub or the arbitrated loop to the out- side world. This means that an unmanaged hub cannot itself notify the administrator if one of its components is defective. A very cost-conscious administrator can build up a small SAN from PC systems, JBODs and unmanaged hubs. However, the upgrade path to a large Fibre Channel SAN is difficult: in larger Fibre Channel SANs it is questionable whether the economical purchase costs compensate for the higher administration costs. In contrast to unmanaged hubs, managed hubs have administration and diagnosis functions like those that are a matter of course in switches and directors.Managed hubs monitor the power supply, serviceability of fans, temperature, and the status of the individual ports. In addition, some managed hubs can, whilst remaining invisible to the connected devices, intervene in higher Fibre Channel protocol layers, for example, to deactivate the port of adevice that frequently sends invalid Fibre Channel frames. Managed hubs, like switches and directors, can inform the system administrator about events via serial interfaces, Telnet, HTTP and SNMP (see also Chapter 8). Finally, the switched hub is mid-way between a hub and a switch. In addition to the properties of a managed hub, with a switched hub several end devices can exchange data at full bandwidth. Fibre Channel switched hubs are cheaper than Fibre Channel switches, so in some cases they represent a cheap alternative to switches. However, it should benoted that only 126 devices can be connected together via hubs and that services such as aliasing and zoning are not available. Furthermore, the protocol cost for the connection or the removal of a device in a loop is somewhat higher than in a fabric (keyword 'Loop Initialisation Primitive Sequence', 'LIP'). Finally, so- alled link extenders should also be mentioned. Fibre Channel supports a maximum cable length of several ten kilometres (Section 3.3.2). A link extender can

increase the maximum cable length of Fibre Channel by transmitting Fibre Channel frames using MAN/WAN techniques such as ATM, SONET or TCP/IP (Figure 3.32).When using link extenders it should be borne in mind that long distances between end devices significantly increase the latency of a connection. Time-critical applications such as database transactions should therefore not run over a link extender. On the other hand,Fibre Channel SANs with link extenders offer new possibilities for applications such as back-up, data sharing and asynchronous data mirroring.

Fibre Channel SAN is a comparatively new technology. In many data centres in which Fibre Channel SANs are used, it is currently (2003) more likely that there will be several islands of small Fibre Channel SANs than one large Fibre Channel SAN (Figure 3.33).Over 80% of the installed Fibre Channel SANs consist only of up to four Fibre Channel switches. A server can only indirectly access data stored on a different SAN via the LAN and a second server. The reasons for the islands of small Fibre Channel SANs are that they are simpler to manage than one large Fibre Channel SAN and that it was often unnecessary to install a large one.

Originally, Fibre Channel SAN was used only as an alternative to SCSI cabling. Until now the possibility of flexibly dividing the capacity of a storage device etween several servers (storage pooling) and the improved availability of dual SANs have been the main reasons for the use of Fibre Channel SANs. Both can be realized very well with several small Fibre Channel SAN islands. However, more and more applications are now exploiting the possibilities offered by a Fibre Channel SAN. Applications such as back-up

 

(Chapter 7), remote data mirroring and data sharing over Fibre Channel SAN and storage virtualization (Chapter 5) require that all servers and storage devices are connected via a single SAN. Incidentally, the connection of Fibre Channel SANs to form a large SAN could be one field of application in which a Fibre Channel director is preferable to a Fibre Channel switch (Figure 3.34). As yet these connections are generally not critical. In the future, however, this could change (extreme situation: virtualization over several data centres). In our opinion these connection points between two storage networks tend to represent a single point of failure, so they should be designed to be particularly fault-tolerant.

Monday, March 24, 2008

FREE TUTORS ON THE FIBRE CHANNEL PROTOCOL STACK FLOW CONTROL (Service classes)

Free Tutors on THE FIBRE CHANNEL PROTOCOL STACK

FC-1: 8b/10b encoding, ordered sets and link control protocolFC-1 defines how data is encoded before it is transmitted via a Fibre Channel cable(8b/10b encoding). FC-1 also describes certain transmission words (ordered sets) that are required for the administration of a Fibre Channel connection (link control protocol). 8b/10b encoding In all digital transmission techniques, transmitter and receiver must synchronize their clock-pulse rates. In parallel buses the bus rate is transmitted via an additional data line. By contrast, in the serial transmission used in Fibre Channel only one data line is available through which the data is transmitted. This means that the receiver must regenerate the transmission rate from the data stream.

The receiver can only synchronize the rate at the points where there is a signal change in the medium. In simple binary encoding (Figure 3.11) this is only the case if the signal changes from '0' to '1' or from '1' to '0'. In Manchester encoding there is a signal change for every bit transmitted. Manchester encoding therefore creates two physical signals for each bit transmitted. It therefore requires a transfer rate that is twice as high as that for binary encoding. Therefore, Fibre Channel – like many other transmission techniques – uses binary encoding, because at a given rate of signal changes more bits can be transmitted than is the case for Manchester encoding. The problem with this approach is that the signal steps that arrive at the receiver are not always the same length (jitter). This means that the signal at the receiver is sometimes a little longer and sometimes a little shorter (Figure 3.12). In the escalator analogy this means that the escalator bucks. Jitter can lead to the receiver losing synchronization with the received signal. If, for example, the transmitter sends a sequence of ten zeros, the receiver cannot decide whether it is a sequence of nine, ten or eleven zeros. If we nevertheless wish to use binary encoding, then we have to ensure that the data stream generates a signal change frequently enough that jitter cannot strike. The so-called 8b/10b encoding represents a good compromise. 8b/10b encoding converts an eight-bit

byte to be transmitted into a ten-bit character, which is sent via the medium instead of the eight-bit byte. For Fibre Channel this means, for example, that a useful transfer rate of 100 MByte/s requires a raw transmission rate of 1 Gbit/s instead of 800 Mbit/s. Incidentally, 8b/10b encoding is also used for the Enterprise System Connection Architecture (ESCON), Serial Storage Architecture (SSA), Gigabit Ethernet and InfiniBand. Finally, it should be noted that 1 Gigabyte Fibre Channel uses the 64b/66b encoding variant for a certain cable type (single lane with serial transmission). Expanding the eight-bit data bytes to ten-bit transmission character gives rise to the following advantages: • In 8b/10b encoding, of all available ten-bit characters, only those that generate a bit

sequence that contains a maximum of five zeros one after the other or five ones one after the other for any desired combination of the ten-bit character are selected. There- fore, a signal change takes place at the latest after five signal steps, so that the clock synchronization of the receiver is guaranteed.

• A bit sequence generated using 8b/10b encoding has a uniform distribution of zeros and ones. This has the advantage that only small direct currents flow in the hardware that processes the 8b/10b encoded bit sequence. This makes the realization of Fibre Channel hardware components simpler and cheaper.

• Further ten-bit characters are available that do not represent eight-bit data bytes. These additional characters can be used for the administration of a Fibre Channel link.

Ordered sets

Fibre Channel aggregates four ten-bit transmission characters to form a 40-bit transmission word. The Fibre Channel standard differentiates between two types of transmission word: data words and ordered sets. Data words represent a sequence of four eight-bit data bytes. Data words may only stand between a Start-of-Frame delimiter (SOF delimiter) and an End-of-Frame delimiter (EOF delimiter).Ordered sets may only stand between an EOF delimiter and a SOF delimiter, with SOF sand EOFs themselves being ordered sets. All ordered sets have in common that they begin with a certain transmission character, the so-called K28.5 character. The K28.5 character includes a special bit sequence that does not occur elsewhere in the data stream. The input channel of a Fibre Channel port can therefore use the K28.5 character to divide the continuous incoming bit stream into 40 bit transmission words when initializing a Fibre Channel link or after the loss of synchronization on a link. Link control protocol With the aid of ordered sets, FC-1 defines various link level protocols for the initialization and Administration of a link. The initialization of a link is the prerequisite for data exchange by means of frames. Examples of link level protocols are the initialization and arbitration of an arbitrated loop.

3.3.4 FC-2: data transfer

FC-2 is the most comprehensive layer in the Fibre Channel protocol stack. It determines how larger data units (for example, a file) are transmitted via the Fibre Channel network. It regulates the flow control that ensures that the transmitter only sends the data at a speed that the receiver can process it. And it defines various service classes that are tailored to the requirements of various applications. Exchange, sequence and frame FC-2 introduces a three-layer hierarchy for the transmission of data (Figure 3.13). At the top layer a so-called exchange defines a logical communication connection between two end devices. For example, each process that reads and writes data could be assigned its own exchange. End devices (servers and storage devices) can simultaneously maintain several exchange relationships, even between the same ports. Different exchanges help the FC-2 layer to deliver the incoming data quickly and efficiently to the orrect receiver in the higher protocol layer (FC-3). A sequence is a larger data unit that is transferred from a transmitter to a receiver. Only one sequence can be transferred after another within an exchange. FC-2 guarantees that sequences are delivered to the receiver in the same order they were sent from the transmitter; hence the name 'sequence'. Furthermore, sequences are only delivered to the next protocol layer up when all frames of the sequence have arrived at the receiver (Figure 3.13). A sequence could represent the writing of a file or an individual database transaction. A Fibre Channel network transmits control frames and data frames. Control frames contain no useful data, they signal events such as the successful delivery of a data frame. Data frames transmit up to 2112 bytes of useful data. Larger sequences therefore have to be broken down into several frames. Although it is theoretically possible to agree upon

different maximum frame sizes, this is hardly ever done in practice. A Fibre Channel frame consists of a header, useful data (payload) and a CRC checksum

(Figure 3.14). In addition, the frame is bracketed by a Start-of-Frame delimiter (SOF) and an End-of-Frame delimiter (EOF). Finally, six filling words must be transmitted by means of a link between two frames. In contrast to Ethernet and TCP/IP, Fibre Channel is an integrated whole: the layers of the Fibre Channel protocol stack are so well harmonizedwith one another that the ratio of payload to protocol overhead is very efficient at up to 98%. The CRC checking procedure is designed to recognize all transmission errors if the underlying medium does not exceed the specified error rate of 10−12 Error correction takes place at sequence level: if a frame of a sequence is wrongly transmitted, the entire sequence is retransmitted. At gigabit speed it is more efficient to resend a complete sequence than to extend the Fibre Channel hardware so that individual lost frames can be resent and inserted in the correct position. The underlying protocol

layer must maintain the specified maximum error rate of 10−12so that this procedures efficient.

Flow control

Flow control ensures that the transmitter only sends data at a speed that the receiver can receive it. Fibre Channel uses the so-called credit model for this. Each credit represents the capacity of the receiver to receive a Fibre Channel frame. If the receiver awards the transmitter a credit of '4', the transmitter may only send the receiver four frames. The transmitter may not send further frames until the receiver has acknowledged the receipt of at least some of the transmitted frames. FC-2 defines two different mechanisms for flow control: end-to-end flow control and link flow control (Figure 3.15). In end-to-end flow control two end devices negotiate the end-to-end credit before the data exchange. The end-to-end flow control is realized on the host bus adapter cards of the end devices. By contrast, link flow control takes place at each physical connection. This is achieved by two communicating ports negotiating the buffer-to-buffer credit. This means that the link flow control also takes place at the Fibre Channel switches.

Service classes

The Fibre Channel standard defines six different service classes for data exchange between end devices. Three of these defined classes (Class 1, Class 2 and Class 3) are realized in products available on the market, with hardly any products providing the connection- oriented Class 1. Almost all new Fibre Channel products (host bus adapters, switches, storage devices) support the service classes Class 2 and Class 3, which realize a packet- oriented service (datagram service). In addition, Class F serves for the data exchange between the switches within a fabric. Class 1 defines a connection-oriented communication connection between two node ports: a Class 1 connection is opened before the transmission of frames. This specifies a route through the Fibre Channel network. Thereafter, all frames take the same route through the Fibre Channel network so that frames are delivered in the sequence in which they were transmitted. A Class 1 connection guarantees the availability of the full bandwidth. A port thus cannot send any other frames while a Class 1 connection is open.

Class 2 and Class 3, on the other hand, are packet-oriented services (datagram services): no dedicated connection is built up, instead the frames are individually routed through the Fibre Channel network. A port can thus maintain several connections at the same time. Several Class 2 and Class 3 connections can thus share the bandwidth. Class 2 uses end-to-end flow control and link flow control. In Class 2 the receiver acknowledges each received frame (acknowledgement, Figure 3.16). This acknowledge-ment is used both for end-to-end flow control and for the recognition of lost frames. A missing acknowledgement leads to the immediate recognition of transmission errors byFC-2, which are then immediately signalled to the higher protocol layers. The higherprotocol layers can thus initiate error correction measures straight away (Figure 3.18).Users of a Class 2 connection can demand the delivery of the frames in the correct order.Class 3 achieves less than Class 2: frames are not acknowledged (Figure 3.17). Thismeans that only link flow control takes place, not end-to-end flow control. In addition, the higher protocol layers must notice for themselves whether a frame has been lost. The loss of a frame is indicated to higher protocol layers by the fact that an expected sequence is not delivered because it has not yet been completely received by the FC-2 layer. A switch may dispose of Class 2 and Class 3 frames if its buffer is full. Due to greater time-outvalues in the higher protocol layers it can take much longer to recognize the loss of aframe than is the case in Class 2 (Figure 3.19).We have already stated that in practice only Class 2 and Class 3 are important. In practice the service classes are hardly ever explicitly configured, meaning that in current Fibre Channel SAN implementations the end devices themselves negotiate whether theycommunicate by Class 2 or Class 3. From a theoretical point of view the two service classes differ in that Class 3 sacrifices some of the communication reliability of Class 2in favour of a less complex protocol. Class 3 is currently the most frequently used service class. This may be because the current Fibre Channel SANs are still very small, so that

frames are very seldom lost or overtake each other. The linking of current Fibre Channel SAN islands to a large SAN could lead to Class 2 playing a greater role in future due toits faster error recognition.

 

 

 

 

 

Buy Vmware Interview Questions & Storage Interview Questions for $150. 100+ Interview Questions with Answers.Get additional free bonus reference materials. You can download immediately even if its 1 AM. You will recieve download link immediately after payment completion.You can buy using credit card or paypal.
----------------------------------------- Get 100 Storage Interview Questions.
:
:
500+ Software Testing Interview Questions with Answers are also available plz email roger.smithson1@gmail.com if you are interested to buy them. 200 Storage Interview Questions word file @ $97

Vmware Interview Questions with Answers $100 Fast Download Immediately after payment.: Get 100 Technical Interview Questions with Answers for $100.
------------------------------------------ For $24 Get 100 Vmware Interview Questions only(No Answers)
Vmware Interview Questions - 100 Questions from people who attended Technical Interview related to Vmware virtualization jobs ($24 - Questions only) ------------------------------------------- Virtualization Video Training How to Get High Salary Jobs Software Testing Tutorials Storage Job Openings Interview Questions

 Subscribe To Blog Feed